Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 294
Filtrar
1.
EuroIntervention ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38742577

RESUMO

BACKGROUND: Transfemoral access is often used when large-bore guide catheters are required for percutaneous coronary intervention (PCI) of complex coronary lesions, especially when large-bore transradial access is contraindicated. Whether the risk of access site complications for these procedures may be reduced by ultrasound-guided puncture is unclear. AIMS: We aimed to show the superiority of ultrasound-guided femoral puncture compared to fluoroscopy-guided access in large-bore complex PCI with regard to access site-related Bleeding Academic Research Consortium 2, 3 or 5 bleeding and/or vascular complications requiring intervention during hospitalisation. METHODS: The ULTRACOLOR Trial is an international, multicentre, randomised controlled trial investigating whether ultrasound-guided large-bore femoral access reduces clinically relevant access site complications compared to fluoroscopy-guided large-bore femoral access in PCI of complex coronary lesions. RESULTS: A total of 544 patients undergoing complex PCI mandating large-bore (≥7 Fr) transfemoral access were randomised at 10 European centres (median age 71; 76% male). Of these patients, 68% required PCI of a chronic total occlusion. The primary endpoint was met in 18.9% of PCI with fluoroscopy-guided access and 15.7% of PCI with ultrasound-guided access (p=0.32). First-pass puncture success was 92% for ultrasound-guided access versus 85% for fluoroscopy-guided access (p=0.02). The median time in the catheterisation laboratory was 102 minutes versus 105 minutes (p=0.43), and the major adverse cardiovascular event rate at 1 month was 4.1% for fluoroscopy-guided access and 2.6% for ultrasound-guided access (p=0.32). CONCLUSIONS: As compared to fluoroscopy-guided access, the routine use of ultrasound-guided access for large-bore transfemoral complex PCI did not significantly reduce clinically relevant bleeding or vascular access site complications. A significantly higher first-pass puncture success rate was demonstrated for ultrasound-guided access. CLINICALTRIALS: gov identifier: NCT04837404.

2.
Neth Heart J ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653922

RESUMO

BACKGROUND: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking. TRIAL DESIGN: The TAVI XS trial is a multicentre, randomised, open-label clinical trial with blinded evaluation of endpoints. A total of 238 patients undergoing transfemoral TAVI will be included. The primary endpoint is the incidence of clinically relevant bleeding (i.e. Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding) of the randomised secondary access site (either diagnostic or pacemaker access, or both) within 30 days after TAVI. Secondary endpoints include time to mobilisation after TAVI, duration of hospitalisation, any BARC type 2, 3 or 5 bleeding, and early safety at 30 days according to Valve Academic Research Consortium­3 criteria. CONCLUSION: The TAVI XS trial is the first randomised trial comparing an upper extremity approach to a lower extremity approach with regard to clinically relevant secondary access site-related bleeding complications. The results of this trial will provide important insights into the safety and efficacy of an upper extremity approach in patients undergoing transfemoral TAVI.

5.
Int J Cardiol ; 406: 131998, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555057

RESUMO

BACKGROUND: Fluid-filled pressure guidewires are unaffected by the previously inevitable hydrostatic pressure gradient (HPG). This study aimed to compare simultaneous pressure measurements with fluid-filled and sensor-tipped pressure guidewires. METHODS: Fifty patients underwent fractional flow reserve (FFR) and Pd/Pa measurement with a fluid-filled and a sensor-tipped pressure guidewire simultaneously. To assess maneuverability, patients were randomized with respect to which pressure guidewire was used to cross the lesion first. Lateral fluoroscopy was used to estimate height difference between catheter tip and distal wire position (and thus HPG). Agreement between pressure measurements was studied. RESULTS: Measurements were performed in LM (4% (n = 2)), LAD (44% (n = 22)), LCX (26% (n = 13)), and RCA (26% (n = 13)). Simultaneous pressure measurements showed excellent agreement (mean FFR difference - 0.01 ± 0.03 (r = 0.959, p < 0.001), mean Pd/Pa difference - 0.01 ± 0.04 (r = 0.929, p < 0.001)). FFR was ≤0.80 in 42.6% (n = 20) with fluid-filled FFR measurements versus 46.8% (n = 22) by sensor-tipped FFR measurements. Mean height difference was 15 ± 34 mm, and strongly dependent on the coronary artery (LAD 45 ± 10 mm, LCX -23 ± 16 mm, RCA -13 ± 17 mm). There was a strong correlation between height difference and difference in pressure ratios between sensor-tipped and fluid-filled pressure guidewires (FFR r = -0.850, p < 0.001; Pd/Par = -0.641, p < 0.001). Largest FFR differences were present in the LAD (-0.04 ± 0.02). After HPG correction, mean difference between HPG-corrected sensor-tipped FFR and fluid-filled FFR was 0.00 ± 0.02, mean Pd/Pa difference was 0.01 ± 0.03. CONCLUSIONS: This study shows excellent overall correlation between FFR and Pd/Pa measurements with both pressure guidewires. Differences measured with fluid-filled and sensor-tipped pressure guidewires are vessel-specific and attributable to hydrostatic pressure gradients (NCT04802681).


Assuntos
Cateterismo Cardíaco , Reserva Fracionada de Fluxo Miocárdico , Humanos , Feminino , Masculino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Pessoa de Meia-Idade , Idoso , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação , Angiografia Coronária/métodos , Desenho de Equipamento , Estudos Prospectivos
6.
Heart Vessels ; 39(4): 299-309, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38367040

RESUMO

Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are invasive techniques used to evaluate the hemodynamic significance of coronary artery stenosis. These methods have been validated through perfusion imaging and clinical trials. New invasive pressure ratios that do not require hyperemia have recently emerged, and it is essential to confirm their diagnostic efficacy. The aim of this study was to validate the resting full-cycle ratio (RFR) and the diastolic pressure ratio (dPR), against [15O]H2O positron emission tomography (PET) imaging. A total of 129 symptomatic patients with an intermediate risk of coronary artery disease (CAD) were included. All patients underwent cardiac [15O]H2O PET with quantitative assessment of resting and hyperemic myocardial perfusion. Within a 2 week period, coronary angiography was performed. Intracoronary pressure measurements were obtained in 320 vessels and RFR, dPR, and FFR were computed. PET derived regional hyperemic myocardial blood flow (hMBF) and myocardial perfusion reserve (MPR) served as reference standards. In coronary arteries with stenoses (43%, 136 of 320), the overall diagnostic accuracies of RFR, dPR, and FFR did not differ when PET hyperemic MBF < 2.3 ml min-1 (69.9%, 70.6%, and 77.1%, respectively) and PET MPR < 2.5 (70.6%, 71.3%, and 66.9%, respectively) were considered as the reference for myocardial ischemia. Non-significant differences between the areas under the receiver operating characteristic (ROC) curve were found between the different indices. Furthermore, the integration of FFR with RFR (or dPR) does not enhance the diagnostic information already achieved by FFR in the characterization of ischemia via PET perfusion. In conclusion, the novel non-hyperemic pressure ratios, RFR and dPR, have a diagnostic performance comparable to FFR in assessing regional myocardial ischemia. These findings suggest that RFR and dPR may be considered as an FFR alternative for invasively guiding revascularization treatment in symptomatic patients with CAD.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Pressão Sanguínea , Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes
7.
Lancet Digit Health ; 6(3): e201-e210, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38395540

RESUMO

BACKGROUND: Unwitnessed out-of-hospital cardiac arrest is associated with low survival chances because of the delayed activation of the emergency medical system in most cases. Automated cardiac arrest detection and alarming using biosensor technology would offer a potential solution to provide early help. We developed and validated an algorithm for automated circulatory arrest detection using wrist-derived photoplethysmography from patients with induced circulatory arrests. METHODS: In this prospective multicentre study in three university medical centres in the Netherlands, adult patients (aged 18 years or older) in whom short-lasting circulatory arrest was induced as part of routine practice (transcatheter aortic valve implantation, defibrillation testing, or ventricular tachycardia induction) were eligible for inclusion. Exclusion criteria were a known bilateral significant subclavian artery stenosis or medical issues interfering with the wearing of the wristband. After providing informed consent, patients were equipped with a photoplethysmography wristband during the procedure. Invasive arterial blood pressure and electrocardiography were continuously monitored as the reference standard. Development of the photoplethysmography algorithm was based on three consecutive training cohorts. For each cohort, patients were consecutively enrolled. When a total of 50 patients with at least one event of circulatory arrest were enrolled, that cohort was closed. Validation was performed on the fourth set of included patients. The primary outcome was sensitivity for the detection of circulatory arrest. FINDINGS: Of 306 patients enrolled between March 14, 2022, and April 21, 2023, 291 patients were included in the data analysis. In the development phase (n=205), the first training set yielded a sensitivity for circulatory arrest detection of 100% (95% CI 94-100) and four false positive alarms; the second training set yielded a sensitivity of 100% (94-100), with six false positive alarms; and the third training set yielded a sensitivity of 100% (94-100), with two false positive alarms. In the validation phase (n=86), the sensitivity for circulatory arrest detection was 98% (92-100) and 11 false positive circulatory arrest alarms. The positive predictive value was 90% (95% CI 82-94). INTERPRETATION: The automated detection of induced circulatory arrests using wrist-derived photoplethysmography is feasible with good sensitivity and low false positives. These promising findings warrant further development of this wearable technology to enable automated cardiac arrest detection and alarming in a home setting. FUNDING: Dutch Heart Foundation (Hartstichting).


Assuntos
Parada Cardíaca , Fotopletismografia , Adulto , Humanos , Estudos Prospectivos , Parada Cardíaca/diagnóstico , Arritmias Cardíacas , Algoritmos
8.
J Clin Med ; 13(3)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38337345

RESUMO

Background The femoral vein is commonly used as a pacemaker access site during transcatheter aortic valve replacement (TAVR). Using an upper arm vein as an alternative access site potentially causes fewer bleeding complications and shorter time to mobilization. We aimed to assess the safety and efficacy of an upper arm vein as a temporary pacemaker access site during TAVR. Methods We evaluated all patients undergoing TAVR in our center between January 2020 and January 2023. Upper arm, femoral, and jugular vein pacemaker access was used in 255 (45.8%), 191 (34.3%), and 111 (19.9%) patients, respectively. Clinical outcomes were analyzed according to pacemaker access in the overall population and in a propensity-matched population involving 165 upper arm and 165 femoral vein patients. Primary endpoint was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 pacemaker access site-related bleeding. Results In the overall population, primary endpoint was lowest for upper arm, followed by femoral and jugular vein access (2.4% vs. 5.8% vs. 10.8%, p = 0.003). Time to mobilization was significantly longer (p < 0.001) in the jugular cohort compared with the other cohorts. In the propensity-matched cohort, primary endpoint showed a trend toward lower occurrence in the upper arm compared with the femoral cohort (2.4% vs. 6.1%, p = 0.10). Time to mobilization was significantly shorter (480 vs. 1140 min, p < 0.001) in the upper arm cohort, with a comparable skin-to-skin time (83 vs. 85 min, p = 0.75). Cross-over from upper arm pacemaker access was required in 17 patients (6.3% of attempted cases via an upper arm vein). Conclusions Using an upper arm vein as a temporary pacemaker access site is safe and feasible. Its use might be associated with fewer bleeding complications and shorter time to mobilization compared with the femoral vein.

9.
Am J Cardiol ; 217: 94-101, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38350507

RESUMO

In the Targeted therapy with a localised abluminal coated, low-dose sirolimus-eluting, biodegreadable polymer coronary stent (TARGET; NCT02520180) All Comers trial the biodegradable polymer (BP) sirolimus-eluting FIREHAWK stent was noninferior to the durable polymer (DP) everolimus-eluting XIENCE stent with respect to target lesion failure (TLF) at 1 and 5 years; however, the long-term safety and efficacy in the setting of acute coronary syndromes (ACS) are not known. We sought to assess the long-term outcomes in ACS versus chronic coronary syndromes (CCS) with BP sirolimus-eluting stent (SES) versus DP everolimus-eluting stent (EES). The TARGET AC study was a multicenter, open-label, noninferiority trial of all comer patients randomly allocated 1:1 to BP SES or DP EES (stratified by ST-elevation myocardial infarction and study site). In this predefined substudy, the outcomes were compared based on clinical presentation (ACS vs CCS) and treatment allocation. A total of 1,653 patients were enrolled (728 with ACS and 922 with CCS), with 94% completing the 5-year follow-up. The baseline characteristics were well-matched between the 2 stent types; however, co-morbidities were more prevalent in the CCS than in the ACS population. TLF (15.5% vs 17.7%, p = 0.24), patient-oriented outcomes (32.0% vs 34.4%, p = 0.31), and stent thrombosis (4.1% vs 3.3%, p = 0.40) were similar between patients with ACS and patients with CCS. In the ACS cohort, the outcomes at 5 years for BP SES versus DP EES were similar for TLF (16.0% vs 14.9%, p = 0.70), ischemia-driven target lesion revascularization (5.6% vs 8.3%, p = 0.17), and definite/probable stent thrombosis (2.7% vs 4.6%, p = 0.18). The same was true for the CCS cohort, with 5-year outcomes for BP SES versus DP EES for TLF (18.0% vs 17.4%, p = 0.82), ischemia-driven target lesion revascularization (6.4% vs 5.0%, p = 0.37), and definite/probable stent thrombosis (3.0% vs 1.8%, p = 0.26). In conclusion, in the TARGET AC trial, 1 in 3 patients had a major adverse event at 5 years, irrespective of CCS or ACS presentation. Long-term, the BP sirolimus-eluting FIREHAWK stent was as safe and effective as the DP everolimus-eluting XIENCE stent across the spectrum of clinical presentations.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Trombose , Humanos , Implantes Absorvíveis , Síndrome Coronariana Aguda/cirurgia , Doença da Artéria Coronariana/terapia , Everolimo/farmacologia , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Fatores de Risco , Sirolimo/farmacologia , Sirolimo/uso terapêutico , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Trombose/etiologia , Resultado do Tratamento
10.
Int J Cardiol ; 402: 131832, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38316189

RESUMO

BACKGROUND: The microvascular resistance reserve (MRR) is an innovative index to assess the vasodilatory capacity of the coronary circulation while accounting for the presence of concomitant epicardial disease. The MRR has shown to be a valuable diagnostic and prognostic tool in the general coronary artery disease (CAD) population. However, considering the fundamental aspects of its assessment and the unique hemodynamic characteristics of women, it is crucial to provide additional considerations for evaluating the MRR specifically in women. AIM: The aim of this study was to assess the diagnostic and prognostic applicability of the MRR in women and assess the potential differences across different sexes. METHODS: From the ILIAS Registry, we enrolled all patients with a stable indication for invasive coronary angiography, ensuring complete physiological and follow-up data. We analyzed the diagnostic value by comparing differences between sexes and evaluated the prognostic value of the MRR specifically in women, comparing it to that in men. RESULTS: A total of 1494 patients were included of which 26% were women. The correlation between MRR and CFR was good and similar between women (r = 0.80, p < 0.005) and men (r = 0.81, p < 0.005). The MRR was an independent and important predictor of MACE in both women (HR 0.67, 0.47-0.96, p = 0.027) and men (HR 0.84, 0.74-0.95, p = 0.007). The optimal cut-off value for MRR in women was 2.8 and 3.2 in men. An abnormal MRR similarly predicted MACE at 5-year follow-up in both women and men. CONCLUSION: The MRR seems to be equally applicable in both women and men with stable coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Masculino , Humanos , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Angiografia Coronária , Prognóstico , Hemodinâmica , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Vasos Coronários/diagnóstico por imagem
11.
Front Cardiovasc Med ; 11: 1352025, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38370159

RESUMO

Coronary atherosclerosis remains a leading cause of morbidity and mortality worldwide. The underlying pathophysiology includes a complex interplay of endothelial dysfunction, lipid accumulation and inflammatory pathways. Multiple structural and inflammatory features of the atherosclerotic lesions have become targets to identify high-risk lesions. Various intracoronary imaging devices have been developed to assess the morphological, biocompositional and molecular profile of the intracoronary atheromata. These techniques guide interventional and therapeutical management and allow the identification and stratification of atherosclerotic lesions. We sought to provide an overview of the inflammatory pathobiology of atherosclerosis, distinct high-risk plaque features and the ability to visualize this process with contemporary intracoronary imaging techniques.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38306632

RESUMO

AIMS: To compare the novel 2D multi-venc and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after TAVR using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND RESULTS: In this prospective study, patients underwent CMR one month after TAVR to assess PVR using 2D multi-venc and 4D flow, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age, 80 years ± 5 [SD], 9 men). Mean RF was 11.7 ± 10.0% using standard 2D flow, 10.6 ± 7.0% using 2D multi-venc flow, and 9.6 ± 7.3% using 4D flow. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, p < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, p < 0.001). Bland-Altman plots revealed no significant bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra- and interobserver reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively; and 0.92 and 0.90 for 4D flow, respectively. CONCLUSION: 2D multi-venc and 4D flow produce accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence, and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.

13.
J Am Heart Assoc ; 13(3): e031850, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38293944

RESUMO

BACKGROUND: The potential impact of exercise on valvular function and aortic diameters in patients with a bicuspid aortic valve remains unclear. Therefore, we assessed the association between lifelong exercise characteristics, valvular dysfunction, and aortic dilatation in patients with a bicuspid aortic valve. METHODS AND RESULTS: In this cross-sectional study, exercise volume (metabolic equivalent of task minutes per week), exercise intensity, and sport type were determined from the age of 12 years to participation using a validated questionnaire. Echocardiography was used to assess aortic stenosis or aortic regurgitation and to measure diameters at the sinuses of Valsalva and ascending aorta. Aortic dilatation was defined as a Z-score ≥2. Four hundred and seven patients (42±17 years, 60% men) were included, of which 133 were sedentary (<500 metabolic equivalent of task minutes per week), 94 active (500-1000 metabolic equivalent of task minutes per week), and 180 highly active (≥1000 metabolic equivalent of task minutes per week). Moderate-to-severe aortic stenosis or aortic regurgitation was present in 23.7% and 20.0%, respectively. Sinuses of Valsalva and ascending aorta diameters were 34.8±6.6 and 36.5±8.1 mm, whereas aortic dilatation was found in 21.6% and 53.4%, respectively. Exercise volume was not associated with valve dysfunction or aortic dilatation. Vigorous intensity and mixed sports were associated with a lower prevalence of aortic stenosis (adjusted odds ratios, 0.43 [0.20-0.94] and adjusted odds ratios, 0.47 [0.23-0.95]). Exercise intensity and sport type were not associated with aortic regurgitation and aortic dilatation. CONCLUSIONS: We found no deleterious associations between lifelong exercise characteristics, valvular dysfunction, and aortic dilatation in patients with a bicuspid aortic valve. Vigorous intensity and exercise in mixed sports were associated with a lower prevalence of moderate-to-severe aortic stenosis. These observations suggest that lifelong exercise does not appear to induce adverse cardiovascular effects in patients with a bicuspid aortic valve.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Masculino , Humanos , Criança , Feminino , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/complicações , Valva Aórtica/diagnóstico por imagem , Estudos Transversais , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/complicações , Dilatação Patológica
14.
Artigo em Inglês | MEDLINE | ID: mdl-38236708

RESUMO

BACKGROUND AND AIMS: The healthcare burden of acute chest pain is enormous. In the randomised ARTICA trial we showed that pre-hospital identification of low-risk patients and rule-out of non-ST-segment elevation acute coronary syndrome (NSTE-ACS) with point-of-care (POC) troponin measurement reduces 30-day healthcare costs with low major adverse cardiac events (MACE) incidence. Here we present the final one-year results of the ARTICA trial. METHODS: Low-risk patients with suspected NSTE-ACS were randomised to pre-hospital rule-out with POC troponin measurement or emergency department (ED) transfer. Primary one-year outcome was healthcare costs. Secondary outcomes were safety, quality of life (QoL) and cost-effectiveness. Safety was defined as one-year MACE, consisting of ACS, unplanned revascularisation or all-cause death. QoL was measured with EuroQol-5D-5 L questionnaires. Cost-effectiveness was defined as one-year healthcare costs difference per QoL difference. RESULTS: Follow-up was completed in all 863 patients. Healthcare costs were significantly lower in the pre-hospital strategy (€1932±€2784 vs €2649±€2750), mean difference €717 (95% confidence interval [CI] €347 to €1087; P < 0.001). In the total population, one-year MACE rate was comparable between groups (5.1% [22/434] in the pre-hospital strategy vs 4.2% [18/429] in the ED strategy; P = 0.54). In the ruled-out ACS population, one-year MACE remained low (1.7% [7/419] vs 1.4% [6/417]), risk difference 0.2% (95% CI -1.4% to 1.9%; P = 0.79). QoL showed no significant difference between strategies. CONCLUSIONS: Pre-hospital rule-out of NSTE-ACS with POC troponin testing in low-risk patients is cost-effective, expressed by a sustainable healthcare costs reduction and no significant effect on QoL. One-year MACE remained low for both strategies. Trial registration: Clinicaltrials.gov: NCT05466591, International Clinical Trials Registry Platform: NTR7346.

17.
Eur Heart J Cardiovasc Imaging ; 25(3): 347-355, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-37812691

RESUMO

AIMS: We examined the association between the symptom-to-reperfusion-time and cardiovascular magnetic resonance (CMR)-derived global strain parameters and transmural infarct extent in ST-segment elevation myocardial infarction (STEMI) patients. METHODS AND RESULTS: The study included 108 STEMI patients who underwent successful primary percutaneous coronary intervention (PPCI). Patients were categorized according to the median symptom-to-reperfusion-time: shorter (<160 min, n = 54) and longer times (>160 min, n = 54). CMR was performed 2-7 days after PPCI and at 1 month. CMR cine imaging was performed for functional assessment and late gadolinium enhancement to evaluate transmural infarct extent. Myocardial feature-tracking was used for strain analysis. Groups were comparable in relation to incidence of LAD disease and pre- and post-PPCI thrombolysis in myocardial infarction (TIMI) flow grades. The mean transmural extent score at follow-up was lower in patients with shorter reperfusion time (P < 0.01). Both baseline and follow-up maximum transmural extent scores were smaller in patients with shorter reperfusion time (P = 0.03 for both). Patients with shorter reperfusion time had more favourable global left ventricular (LV) circumferential strain (baseline, P = 0.049; follow-up, P = 0.01) and radial strain (baseline, P = 0.047; follow-up, P < 0.01), whilst LV longitudinal strain appeared comparable for both baseline and follow-up (P > 0.05 for both). In multi-variable regression analysis including all three strain directions, baseline LV circumferential strain was independently associated with the mean transmural extent score at follow-up (ß=1.89, P < 0.001). CONCLUSION: In STEMI patients, time-to-reperfusion was significantly associated with smaller transmural extent of infarction and better LV circumferential and radial strain. Moreover, infarct transmurality and residual LV circumferential strain are closely linked.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Meios de Contraste , Gadolínio , Coração , Reperfusão
18.
JACC Asia ; 3(6): 865-877, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38155797

RESUMO

Background: Coronary pressure- and flow-derived parameters have prognostic value. Objectives: This study aims to investigate the individual and combined prognostic relevance of pressure and flow parameters reflecting resting and hyperemic conditions. Methods: A total of 1,971 vessels deferred from revascularization after invasive pressure and flow assessment were included from the international multicenter registry. Abnormal resting pressure and flow were defined as distal coronary pressure/aortic pressure ≤0.92 and high resting flow (1/resting mean transit time >2.4 or resting average peak flow >22.7 cm/s), and abnormal hyperemic pressure and flow as fractional flow reserve ≤0.80 and low hyperemic flow (1/hyperemic mean transit time <2.2 or hyperemic average peak flow <25.0 cm/s), respectively. The clinical endpoint was target vessel failure (TVF), myocardial infarction (MI), or cardiac death at 5 years. Results: The mean % diameter stenosis was 46.8% ± 16.5%. Abnormal pressure and flow were independent predictors of TVF and cardiac death/MI (all P < 0.05). The risk of 5-year TVF or MI/cardiac death increased proportionally with neither, either, and both abnormal resting pressure and flow, and abnormal hyperemic pressure and flow (all P for trend < 0.001). Abnormal resting pressure and flow were associated with a higher rate of TVF or MI/cardiac death in vessels with normal fractional flow reserve; this association was similar for abnormal hyperemic pressure and flow in vessels with normal resting distal coronary pressure/aortic pressure (all P < 0.05). Conclusions: Abnormal resting and hyperemic pressure and flow were independent prognostic predictors. The abnormal flow had an additive prognostic value for pressure in both resting and hyperemic conditions with complementary prognostic between resting and hyperemic parameters.

19.
Neth Heart J ; 31(12): 489-499, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37910336

RESUMO

OBJECTIVE: The importance of revascularisation of significant coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is unclear. Despite the lack of randomised controlled trials comparing different revascularisation strategies, guidelines currently recommend percutaneous coronary intervention (PCI) in patients with significant proximal CAD undergoing TAVI. METHODS: In this systematic review and meta-analysis, a systematic search was conducted to identify studies comparing TAVI with and without PCI in patients with significant CAD on pre-TAVI coronary angiography. Endpoints were all-cause mortality, cardiac death, stroke, myocardial infarction and major bleeding. RESULTS: In total, 14 studies were included, involving 3838 patients, of whom 1806 (47%) underwent PCI before TAVI. All-cause mortality did not differ significantly between TAVI with and without preceding PCI at 30 days, 1 year and > 1 year. There were no significant differences in risk of cardiac death, stroke or myocardial infarction between the groups. However, TAVI performed with PCI resulted in a higher risk of major bleeding within 30 days after TAVI (odds ratio: 0.66; 95% confidence interval: 0.46-0.94). CONCLUSION: This systematic review and meta-analysis showed no significant differences in clinical outcomes between patients with concomitant significant CAD who were treated with TAVI with and without preceding PCI at both short- and long-term follow-up. However, there was a higher risk of major bleeding at 30 days in patients undergoing TAVI with preceding PCI. In the context of serious risk of bias in the included studies, results of randomised controlled trials are warranted.

20.
Open Heart ; 10(2)2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38011992

RESUMO

OBJECTIVE: Prehospital rule-out of non-ST-segment elevation acute coronary syndrome (NSTE-ACS) in low-risk patient with a point-of-care troponin measurement reduces healthcare costs with similar safety to standard transfer to the hospital. Risk stratification is performed identical for men and women, despite important differences in clinical presentation, risk factors and age between men and women with NSTE-ACS. Our aim was to compare safety and healthcare costs between men and women in prehospital identified low-risk patients with suspected NSTE-ACS. METHODS: In the Acute Rule-out of non-ST-segment elevation acute coronary syndrome in the (pre)hospital setting by HEART (History, ECG, Age, Risk factors and Troponin) score assessment and a single poInt of CAre troponin randomised trial, the HEAR (History, ECG, Age and Risk factors) score was assessed by ambulance paramedics in suspected NSTE-ACS patients. Low-risk patients (HEAR score ≤3) were included. In this substudy, men and women were compared. Primary endpoint was 30-day major adverse cardiac events (MACE), secondary endpoints were 30-day healthcare costs and the scores for the HEAR score components. RESULTS: A total of 863 patients were included, of which 495 (57.4%) were women. Follow-up was completed in all patients. In the total population, MACE occurred in 6.8% of the men and 1.6% of the women (risk ratio (RR) 4.2 (95% CI 1.9 to 9.2, p<0.001)). In patients with ruled-out ACS (97% of the total population), MACE occurred in 1.4% of the men and in 0.2% of the women (RR 7.0 (95% CI 2.0 to 14.2, p<0.001). Mean healthcare costs were €504.55 (95% CI €242.22 to €766.87, p<0.001) higher in men, mainly related to MACE. CONCLUSIONS: In a prehospital population of low-risk suspected NSTE-ACS patients, 30-day incidence of MACE and MACE-related healthcare costs were significantly higher in men than in women. TRIAL REGISTRATION NUMBER: NCT05466591.


Assuntos
Síndrome Coronariana Aguda , Serviços Médicos de Emergência , Masculino , Humanos , Feminino , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/epidemiologia , Medição de Risco , Dor no Peito , Troponina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA